Optical fiber cable - Wikipedia. A TOSLINK optical fiber cable with a clear jacket. These cables are used mainly for digital audio connections between devices. An optical fiber cable is a cable containing one or more optical fibers that are used to carry light. The optical fiber elements are typically individually coated with plastic layers and contained in a protective tube suitable for the environment where the cable will be deployed. Different types of cable . In practical fibers, the cladding is usually coated with a layer of acrylate polymer or polyimide. This coating protects the fiber from damage but does not contribute to its optical waveguide properties. Individual coated fibers (or fibers formed into ribbons or bundles) then have a tough resinbuffer layer and/or core tube(s) extruded around them to form the cable core. Several layers of protective sheathing, depending on the application, are added to form the cable. Rigid fiber assemblies sometimes put light- absorbing (. This reduces cross- talk between the fibers, or reduces flare in fiber bundle imaging applications. Fiber Optic Patch Cables. Welcome to the fiber optic patch cable section of our online cable superstore! Select Cables by Connector Type. Fiber Optic Patch Cable Color Codes, Wholesale Various High Quality Fiber Optic Patch Cable Color Codes Products from Global Fiber Optic Patch Cable Color Codes. Amazon.com: fiber optic cable color code. Platinum Tools Sealsmart Coax Stripper Yellow For Mini RG59 Cable Color Codes 2 Level Strip. Fiber Optic Cable And Connector Color Codes. Fiber Number: Color: 1. Fiber Patch Cord Connector and Color Codes; Patch Cord. E2000 to ST Fiber Patch Cable Overview. Shenzhen Ting Esun Communication technology Co.is a leading professional. Fiber Optic Patch Cords, MPO. Fiber Optic Cable & Connector Color Codes; MORE+. Twaron or Kevlar), in a lightweight plastic cover to form a simple cable. Each end of the cable may be terminated with a specialized optical fiber connector to allow it to be easily connected and disconnected from transmitting and receiving equipment. The individual fiber cable strands within the junction box are visible. In loose- tube construction the fiber is laid helically into semi- rigid tubes, allowing the cable to stretch without stretching the fiber itself. This protects the fiber from tension during laying and due to temperature changes. Loose- tube fiber may be . Dry block offers less protection to the fibers than gel- filled, but costs considerably less. Instead of a loose tube, the fiber may be embedded in a heavy polymer jacket, commonly called . Tight buffer cables are offered for a variety of applications, but the two most common are . Breakout cables normally contain a ripcord, two non- conductive dielectric strengthening members (normally a glass rod epoxy), an aramid yarn, and 3 mm buffer tubing with an additional layer of Kevlar surrounding each fiber. The ripcord is a parallel cord of strong yarn that is situated under the jacket(s) of the cable for jacket removal. These fiber units are commonly bundled with additional steel strength members, again with a helical twist to allow for stretching. A critical concern in outdoor cabling is to protect the fiber from contamination by water. This is accomplished by use of solid barriers such as copper tubes, and water- repellent jelly or water- absorbing powder surrounding the fiber. Finally, the cable may be armored to protect it from environmental hazards, such as construction work or gnawing animals. Undersea cables are more heavily armored in their near- shore portions to protect them from boat anchors, fishing gear, and even sharks, which may be attracted to the electrical power that is carried to power amplifiers or repeaters in the cable. Modern cables come in a wide variety of sheathings and armor, designed for applications such as direct burial in trenches, dual use as power lines, installation in conduit, lashing to aerial telephone poles, submarine installation, and insertion in paved streets. Capacity and market. In some cases, only a small fraction of the fibers in a cable may be actually . Companies can lease or sell the unused fiber to other providers who are looking for service in or through an area. The initial fiber strength, as well as its change with time, must be considered relative to the stress imposed on the fiber during handling, cabling, and installation for a given set of environmental conditions. There are three basic scenarios that can lead to strength degradation and failure by inducing flaw growth: dynamic fatigue, static fatigues, and zero- stress aging. Telcordia GR- 2. 0, Generic Requirements for Optical Fiber and Optical Fiber Cable, contains reliability and quality criteria to protect optical fiber in all operating conditions. For the indoor plant, similar criteria are in Telcordia GR- 4. Generic Requirements for Indoor Fiber Optic Cable. The material determines the mechanical robustness, aging due to UV radiation, oil resistance, etc. Nowadays PVC is being replaced by halogen free alternatives, mainly driven by more stringent regulations. Fiber material. They offer widely different characteristics and find uses in very different applications. Generally, plastic fiber is used for very short range and consumer applications, glass fiber is used for short/medium range (multi- mode) and long range (single- mode) telecommunications. Connectors with a plastic shell (such as SC connectors) typically use a color- coded shell. Standard color codings for jackets and boots (or connector shells) are shown below: Connector Boot. Meaning. Comment. Fiber Color Identification Chart. Fiber Optic Color Code Chart For 144 and. Multimode 62.5/125 Duplex Fiber Patch Cable is terminated with one LC. Cable Length: 3.3 ft . Startech.com - Fiber Optic Cable. Startech.com - Fiber Optic Cable. Blue. Physical Contact (PC), 0. Sometimes used to connect external pump lasers or Raman pumps. Remark: It is also possible that a small part of a connector is additionally colour- coded, e. This additional colour coding indicates the correct port for a patchcord, if many patchcords are installed at one point. Multi- fiber cables. The identification scheme used by Corning Cable Systems is based on EIA/TIA- 5. This standard allows for fiber units to be identified by means of a printed legend. This method can be used for identification of fiber ribbons and fiber subunits. The legend will contain a corresponding printed numerical position number and/or color for use in identification. In the UK the colour codes for COF2. Each 1. 2 fibre bundle or element within a Cable Optical Fibre 2. Each element is in a tube within the cable (not a blown fibre tube) The cable elements start with the red tube and are counted around the cable to the green tube. Active elements are in white tubes and yellow fillers or dummies are laid in the cable to fill it out depending on how many fibres and units exists - can be up to 2. The cable has a central strength member normally made from fiberglass or plastic. There is also a copper conductor in external cables. Propagation speed and delay. This is the speed of light in vacuum divided by the refractive index of the glass used, typically around 1. Thus the round- trip delay time for 1. B/km at 1. 31. 0/1. Very high quality singlemode fiber intended for long distance applications is specified at a loss of 0. B/km at 1. 55. 0 nm. Plastic optical fiber is large core (about 1mm) fiber suitable only for short, low speed networks such as within cars. However, the glass fibers will transmit visible light somewhat, which is convenient for simple testing of the fibers without requiring expensive equipment. Splices can be inspected visually, and adjusted for minimal light leakage at the joint, which maximizes light transmission between the ends of the fibers being joined. The charts at . The eye's natural defense against sudden exposure to bright light is the blink reflex, which is not triggered by infrared sources. In some cases the power levels are high enough to damage eyes, particularly when lenses or microscopes are used to inspect fibers that are emitting invisible infrared light. Inspection microscopes with optical safety filters are available to guard against this. More recently indirect viewing aids are used, which can comprise a camera mounted within a handheld device, which has an opening for the connectorized fiber and a USB output for connection to a display device such as a laptop. This makes the activity of looking for damage or dirt on the connector face much safer. Small glass fragments can also be a problem if they get under someone's skin, so care is needed to ensure that fragments produced when cleaving fiber are properly collected and disposed of appropriately. Hybrid cables. In these cables, the optical fibers carry information, and the electrical conductors are used to transmit power. These cables can be placed in several environments to serve antennas mounted on poles, towers, and other structures. According to Telcordia. GR- 3. 17. 3,Generic Requirements for Hybrid Optical and Electrical Cables for Use in Wireless Outdoor Fiber To The Antenna (FTTA) Applications, these hybrid cables have optical fibers, twisted pair/quad elements, coaxial cables and/or current- carrying electrical conductors under a common outer jacket. The power conductors used in these hybrid cables are for directly powering an antenna or for powering tower- mounted electronics exclusively serving an antenna. They have a nominal voltage normally less than 6. VDC or 1. 08/1. 20 VAC. Considerations such as fire resistance, Nationally Recognized Testing Laboratory (NRTL) Listings, placement in vertical shafts, and other performance- related issues need to be fully addressed for these environments. Since the voltage levels and power levels used within these hybrid cables vary, electrical safety codes consider the hybrid cable to be a power cable, which needs to comply with rules on clearance, separation, etc. Innerducts. They provide a means for subdividing conventional conduit that was originally designed for single, large- diameter metallic conductor cables into multiple channels for smaller optical cables. Innerducts are typically small- diameter, semi- flexible subducts. According to Telcordia. GR- 3. 56, there are three basic types of innerduct: smoothwall, corrugated, and ribbed. The need for a specific characteristic or combination of characteristics, such as pulling strength, flexibility, or the lowest coefficient of friction, dictates the type of innerduct required. Beyond the basic profiles or contours (smoothwall, corrugated, or ribbed), innerduct is also available in an increasing variety of multiduct designs. Multiduct may be either a composite unit consisting of up to four or six individual innerducts that are held together by some mechanical means, or a single extruded product having multiple channels through which to pull several cables.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. Archives
December 2016
Categories |